MOBIL OIL CORP -- DTE OIL EXTRA HEAVY -- 9150-00-068-4164
===================== Product Identification =====================
Product ID:DTE OIL EXTRA HEAVY
MSDS Date:12/13/1994
FSC:9150
NIIN:00-068-4164
=== Responsible Party ===
Company Name:MOBIL OIL CORP
Address:3225 GALLOWS RD
City:FAIRFAX
State:VA
ZIP:22037
Country:US
Info Phone Num:800-662-4525;703-849-3265
Emergency Phone Num:609-737-4411;800-424-9300(CHEMTREC)
CAGE:1E969
=== Contractor Identification ===
Company Name:MOBIL OIL CORP
Address:530 EAST SWEDESFORD ROAD
Box:1031
City:VALLEY FORGE
State:PA
ZIP:19482
Country:US
Phone:703-849-3265
CAGE:1E969
Company Name:MOBIL OIL CORP ENVIRONMENTAL AFFAIRS & TOXICOLOGY
Address:PENNINGTON-ROCKY HILL RD
Box:City:PENNINGTON
State:NJ
ZIP:08534
Country:US
CAGE:0AHK0
============= Composition/Information on Ingredients =============
Ingred Name:ZINC (ELEMENTAL ANALYSIS) (SARA 313) (CERCLA)
CAS:7440-66-6
RTECS #:ZG8600000
Fraction by Wt: 0.08%
OSHA PEL:N/K
ACGIH TLV:N/K
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:PHOSPHORODITHOIC ACID, O-O-D1 C1-14-ALKYL ESTERS, ZINC
SALTS (2:1) (ZDDP)
CAS:68649-42-3
Fraction by Wt: 0.45%
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:VOLATILE ORGANIC COMPOUND: EXEMPT IN U.S.
RTECS #:9999999VO
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:SPILL PROC: SPILL NOTIFY CHEMTREC (800) 424-9300. ABSORB ON
FIRE RETARDANT TREATED SAWDUST, DIATOMACEOUS EARTH, (ING 5)
RTECS #:9999999ZZ
Ingred Name:ING 4: ETC. SHOVEL UP & DISP OF AT APPROP WASTE DISP
FACILITY I/A/W CURRENT APPLIC LAWS & REGS, & PROD CHARACTS (ING 6)
RTECS #:9999999ZZ
Ingred Name:ING 5: AT TIME OF DISP. PREVENT SPILLS FROM ENTERING STORM
SEWERS OR DRAINS AND CONTACT WITH SOIL.
RTECS #:9999999ZZ
Ingred Name:WASTE DISP METH: GOVERNMENT APPRVD WASTE DISP FACILITY. USE
OF THESE METHS IS SUBJECT TO USER COMPLIANCE WITH (ING 8)
RTECS #:9999999ZZ
Ingred Name:ING 7: APPLIC LAWS & REGS & CONSIDERATION OF PROD CHARACTS
AT TIME OF DISP. UNUSED PROD, IN MFR OPINION, IS NOT (ING 9)
RTECS #:9999999ZZ
Ingred Name:ING 8: SPECIFICALLY LISTED BY EPA AS HAZ WASTE (40 CFR,
PART 261D), NOR IS IT FORMULATED TO CONTAIN MATLS WHICH (ING 10)
RTECS #:9999999ZZ
Ingred Name:ING 9: ARE LISTED AS HAZ WASTES. IT DOES NOT EXHIBIT HAZ
CHARACTS OF IGNITABILITY, CORROSIVITY/REACTIVITY & (ING 11)
RTECS #:9999999ZZ
Ingred Name:ING 10: IS NOT FORMULATED W/CONTAMINANTS AS DETERMINED BY
TOXICITY CHARACTERISTIC LEACHING PROCEDURE (TCLP). (ING 12)
RTECS #:9999999ZZ
Ingred Name:ING 11: HOWEVER, USED PRODUCT MAY BE REGULATED. DISPOSE OF
I/A/W LOCAL, STATE AND FEDERAL REGULATIONS .
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50 (ORAL RAT): > 2000 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:PRODUCT ASSESSED IN ACCORDANCE W/OSHA
29 CFR 1910.1200 & DETERMINED NOT TO BE HAZARDOUS. ACUTE
TOXICOLOGY: ORAL TOX (RATS)/DERM TOX (RABBITS): PRACTICALLY
NON-TOXIC. EYE IRRIT (RABBITS)/SKIN IRRIT (RA BBITS): PRACTICALLY
NON-IRRIT. ACUTE TOX RSLTS SUMMARIZED ABOVE ARE BASED ON TESTING OF
REPRESENTATIVE MOBIL PRODUCTS.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:NO SIGNIFICANT EFFECTS EXPECTED.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYES: FLUSH THORO W/WATER FOR AT LEAST 15 MIN. IF IRRIT
OCCURS, CALL MD. SKIN: WASH CONT AREAS W/SOAP & WATER. HIGH PRESS
ACCIDENTAL INJECTION THRU SKIN REQUIRES IMMED MED ATTN FOR POSS
INCISION, IRRI GATION &/DEBRIDEMENT. INHAL: NOT EXPECTED TO BE A
PROBLEM. REMOVE TO FRESH AIR. SUPPORT BRTHG (GIVE OXYGEN/ARTF RESP)
. INGEST: NOT EXPECTED TO BE A PROBLEM. HOWEVER, IF >1/2 LITER (SUP
DAT)
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:>439F,>226C
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL AND WATER FOG.
Fire Fighting Procedures:WEAR NIOSH APPRVD SCBA & FULL PROT EQUIP .
WATER/FOAM MAY CAUSE FROTHING. USE WATER TO KEEP FIRE-EXPOSED
CONTRS COOL. WATER SPRAY MAY BE USED TO (SUP DAT)
Unusual Fire/Explosion Hazard:PRESSURIZED MISTS MAY FORM A FLAMMABLE
MIXTURE.
================== Accidental Release Measures ==================
Spill Release Procedures:RPT SPILLS AS REQUIRED TO APPROP AUTH. U.S.
COAST GUARD REGS REQUIRE IMMED REPORTING OF SPILLS THAT COULD REACH
ANY WATERWAY INCL INTERMITTENT DRY CREEKS. RPT SPILL TO COAST GUARD
TOLL FREE NUMBER (80 0) 424-8802. IN CASE OF ACCIDENT/ROAD (ING 4)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT STORE IN OPEN OR UNLABELLED
CONTAINERS. STORE AWAY FROM STRONG OXIDIZING AGENTS OR COMBUSTIBLE
MATERIAL.
Other Precautions:HIGH PRESSURE INJECTION UNDER THE SKIN MAY OCCUR DUE
TO THE RUPTURE OF PRESSURIZED LINES. ALWAYS SEEK MEDICAL ATTENTION.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NO SPECIAL REQUIREMENTS UNDER ORDINARY
CONDITIONS OF USE AND WITH ADEQUATE VENTILATION. USE NIOSH APPROVED
RESPIRATOR FOR EXPOSURE OF CONCERN .
Ventilation:NO SPECIAL REQUIREMENTS UNDER ORDINARY CONDITIONS OF USE
AND WITH ADEQUATE VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:GOOD PERSONAL HYGIENE PRACTICES SHOULD ALWAYS
BE FOLLOWED.
Supplemental Safety and Health
FIRE FIGHT PROC: FLUSH SPILLS AWAY FROM EXPOS. PVNT RUNOFF FROM FIRE
CTL/DILUTION FROM ENTERING STREAMS, SEWERS/DRINKING WATER SUPPLY.
FIRST AID PROC: (PINT) INGESTED, IMMED GIVE 1-2 GLASSES OF WATER &
CALL MD, HOSPITAL EMER ROOM/POIS CTL CTR FOR ASSIST. DO NOT INDUCE
VOMIT/GIVE ANYTHING BY MOUTH TO AN UNCON PERSON.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:>601F,>316C
Vapor Pres:<0.1 @ 20C
Vapor Density:>2.0
Spec Gravity:0.89
Solubility in Water:NEGLIGIBLE
Appearance and Odor:DARK AMBER LIQUID, MILD ODOR
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:EXTREME HEAT.
Hazardous Decomposition Products:CARBON MONOXIDE, METAL OXIDES,
ELEMENTAL OXIDES.
==================== Disposal Considerations ====================
Waste Disposal Methods:PROD IS SUITABLE FOR BURNING IN ENCLSD,
CONTROLLED BURNER FOR FUEL VALUE/DISP BY SUPERVISED INCIN. SUCH
BURNING MAY BE LIMITED PURSUANT TO RCRA. IN ADDN, PROD IS SUITABLE
FOR PROCESSING BY APPRVD RECY CLING FACILITY/CAN BE DISPOSED OF AT
ANY (ING 7)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.